Menu

Details

A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability

A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability

author:
Tae Mok Gwon
 
publisher:
Springer Singapore
 
edition:
1
 
publication year:
2018
 
language:
English
 
ISBN:
9789811304729
 
pages:
107
 
format:
ileio (leitura online e APP)
 

This book describes the design, fabrication and evaluation of a polymer-based neural interface for a cochlear electrode array, reviewed in terms of fabrication process, functionality, and reliability. Polymer-based devices have attracted attention in the neural prosthetic field due to their flexibility and compatibility with micro-fabrication process. A liquid crystal polymer (LCP) is an inert, highly water-resistant polymer suitable for the encapsulation of electronic components and as a substrate material for fabricating neural interfaces. The author has designed, fabricated, and evaluated an LCP-based cochlear electrode array for an improved polymer-based cochlear implant. The thesis deals with 3 key topics: atraumatic deep insertion, tripolar stimulation, and long-term reliability. Atraumatic insertion of the intracochlear electrode and resulting preservation of residual hearing have become essential in state–of-the-art cochlear implantation. A novel tapered design of an LCP-based cochlear electrode array is presented to meet such goals. For high-density and pitch-recognizable cochlear implant, channel interaction should be avoided. Local tripolar stimulation using multi-layered electrode sites are shown to achieve highly focused electrical stimulation. This thesis addresses another vital issue in the polymer-based neural implants: the long-term reliability issue. After suggesting a new method of forming mechanical interlocking to improve polymer-metal adhesion, the author performs accelerating aging tests to verify the method’s efficacy. The aforementioned three topics have been thoroughly examined through various in vitro and in vivo studies. Verification foresees the development of LCP-based cochlear electrode array for an atraumatic deep insertion, advanced stimulation, and long-term clinical implant.

Informação indisponível.

Personal
License type Print permissions
Acesso Perpétuo unlimited


Online reading: one user per session (no simultaneous sessions allowed)
Offline reading (with APP): maximum of 2 simultaneous devices

Institutional

If the e-book you want to buy must be used by your library or instituition, please contact MARKA Lda for more information:

Email: [email protected]
Phone: + (351) 21 322 4040
Fax: + (351) 21 322 4044


Address:
Rua dos Correeiros, 61,3º Andar
1100-162 Lisboa
Portugal